Micro Modular Data Center Solution
A factory-integrated data center for sites without room to build one.
The Problem
Customer Challenge
Enterprises and banks need dedicated data rooms at branch or regional sites, but traditional construction of power, cooling and fire protection systems is slow, requires specialist contractors, and is hard to replicate consistently across many sites.
The Approach
Solution Architecture
Wandtung pre-integrates IT cabinets, UPS, PDU, cooling, battery, fire suppression, access control and environmental monitoring into a standardized micro module, factory tested as a complete system and shipped ready for on-site placement and commissioning.
System
System Components
IT Cabinets
Single-row or dual-row cabinets with containment.
UPS & PDU
Integrated power protection and distribution sized to module capacity.
Cooling
In-row or precision cooling matched to enclosed module volume.
Fire Suppression
Automatic gas-based suppression system.
Access Control & Monitoring
Card/biometric access and centralized environmental monitoring.
Architecture
How It Works
- 1
Module is engineered and pre-assembled at the factory as a complete system.
- 2
Power, cooling, fire suppression and monitoring are integrated and function-tested before shipment.
- 3
Module is delivered to site and connected to utility power, network and building management.
- 4
Centralized monitoring reports power, environment and security status to the operator.
Configuration
Product Configuration
Smart Micro Module Data Center
All-in-one micro data center with integrated UPS, precision cooling and touchscreen monitoring, 1-5 bay expansion.
Intelligent PDU
Network-managed rack power distribution with monitoring, metering and remote switching.
Intelligent Cabinet
Cabinet with integrated environmental and access monitoring for lights-out sites.
Advantages
Technical Advantages
- Consistent, repeatable deployment across multiple branch/regional sites
- Reduced on-site construction time versus a traditional built data room
- Factory quality control before the system ever reaches site
Process
Deployment Process
Step 1
Site & Capacity Assessment
Confirm space, power availability and IT load target.
Step 2
Module Configuration
Select row configuration, redundancy and cooling type.
Step 3
Factory Build & Test
Integrate and test the complete module before shipment.
Step 4
Site Placement & Connection
Position module, connect utility, network and BMS.
Step 5
Commissioning
Full-system verification and operator handover.
Deployment
Typical Applications
FAQ
Frequently Asked Questions
A micro modular data center is a factory pre-integrated system combining IT cabinets, power distribution, UPS, cooling, fire suppression, access control and monitoring into a single standardized unit, reducing on-site construction time compared to a traditional built data room.
Request This Solution
Tell us about your project and our engineering team will propose a configuration matched to your site requirements.